Agajanian & Associates Inc and Smock Real Estate Incorporated
Prepared for
32nd Street LP
Via
Kidder Mathews
Program
6 offices + conference + studio
Date
September 11, 2026
Summary
How we are asking the 5th floor suite to be built.
The floor is already being remodeled, so everything here is inexpensive to incorporate now and a change order later. We would like it reflected before the drawings are finalized.
Layout
Six offices, conference room, studio, common area
Where it sits on the floor
Our layout overlaid on the level 5 reflected ceiling plan, so the suite reads in context with the core, the corridor and the open floor.
These are AI renderings, produced to show design direction. They are not construction documents and are not to scale. Dimensions and room locations are governed by the floor plan above.
We understand the landlord's scope is the standard build-out plus the specific items listed on this page. Furniture, kitchen cabinetry and millwork, appliances, artwork, plants and decor shown in the renderings are ours, not asks.
Ceilings
Exposed across the common area, sealed above each enclosed room
Common area ceiling fully exposed and continuous. Enclosed rooms keep a standard grid with standard lay-in fixtures.
For the enclosed rooms to work for client calls, each needs a solid sealed lid above its grid rather than an open plenum. It is concealed, so the common area ceiling still reads as one uninterrupted plane.
Common areaFully exposed structure, continuous. No dropped ceiling or soffits across the open span.
Enclosed roomsStandard suspended grid, standard lay-in fixtures.
Above each gridSolid gypsum lid, sealed to the walls.
Return airDucted return or lined transfer boot per enclosed room. An open transfer grille would defeat the lid.
The renderings above show the effect: structure running unbroken over the top of the enclosed rooms.
Doors
Full lite glass panel, solid core at the studio
Offices and conference room
One lite clear glass, full height, in a solid painted frame. Swing door with perimeter stop and weatherstrip.
Studio
Same door and frame, solid core with no glass. This room is used for calls and recording.
Reference image shown for style. Equivalent building standard product is fine.
Interior windowsNone at the private offices. One at the conference room. This supersedes the letter of intent, which calls for large interior windows at all six offices. The glass in the office doors provides the borrowed light.
SwingsHinge sides and swing direction shown on the plan. Doors to open flat against the entry wall.
Clear width32 inch minimum clear at every opening.
Flooring
Polished concrete in the common area, carpet in the offices
We are asking for the common area slab to be polished rather than covered with resilient plank. The floor below is the finish we are after.
Matte satin polish, salt and pepper, no aggregate exposure, as shown in the renderings above. Natural colour variation in the slab is expected and wanted.
Common areaMechanically polished concrete. Class B fine aggregate, salt and pepper. Level 2 satin, 400 to 800 grit. Lithium silicate densifier. Penetrating stain guard, no topical film coating.
OfficesBuilding standard carpet, per the letter of intent.
Window coverings
Manual roller shades at every perimeter window
TypeManual roller shades, solar screen fabric. Not motorized.
FabricNeutral colour, 3 to 5 percent openness, so glare is controlled and the view is kept.
LocationsAll perimeter windows in the six offices and the conference room.
Lighting, power and HVAC
SwitchingIndividual switch in every enclosed room. The existing suite switches roughly half the floor at a time.
ZoningTwo thermostats, two zones: perimeter and interior (shown on the plan). The offices sit on the window line and will run warm in the afternoon while the interior runs cold on a single zone.
DataOne data drop in the studio. Standard power throughout.
Shared restrooms
Both restrooms with a toilet and a urinal
The floor restrooms are single occupancy. On the other floors, one has a toilet and a urinal and the other has only a toilet. We are asking for both 5th floor restrooms to have both fixtures, so the two rooms are identical.
FixturesA toilet and a urinal in both rooms. Same urinal already installed elsewhere in the building. The change is that the second room gets one as well. The two rooms are the same size and adjacent, so the wet wall is already there.
LocksMechanical pushbutton locks in place of keyed. Keypad outside, free egress inside.
Simplex mechanical push button lockset, ADA compliant, chrome
Example model. Mechanical lever set, no wiring or batteries. Code entry outside, plain lever inside so the door always opens from within.
Reference image and model shown for style. Equivalent building standard product is fine.