Tenant requirements · Suite 500
Agajanian & Associates Inc and Smock Real Estate Incorporated
Our layout, measurement position, and build requirements for the 5th floor, in one place.
The floor is already being remodeled, so everything here is inexpensive to incorporate now and a change order later. We would like it reflected before the drawings are finalized.
Open the interactive floor plan to click into any room, wall, door, or fixture.
| Room | Usable |
|---|---|
| Office 1 | 100 sf |
| Office 2 | 80 sf |
| Office 3 | 152 sf |
| Office 4 | 120 sf |
| Office 5 | 120 sf |
| Office 6 | 120 sf |
| Conference room | 74 sf |
| Studio | 63 sf |
| Common area, reception and kitchen | 434 sf |
| Total usable | 1,263 sf |
The letter of intent lists approximately 1,500 rentable with exact size to be determined. Our layout measures 1,263 usable, which at this building's load factor is 1,435 rentable.
Usable, as drawn
1,263 sf
Load factor
13.61%
Rentable
1,435 sf
The 13.61% comes from Agajanian & Associates' current lease in this building. Suite 220 is stated at 985 rentable and 867 usable. We have applied the landlord's own standard rather than proposing a new one.
Please state both figures in the lease, as the Suite 220 lease does, and confirm the premises by measurement to a published BOMA standard with the 5th floor common area factor disclosed.
| At 1,500 rsf | At 1,435 rsf | |
|---|---|---|
| Year one, monthly | $5,032.50 | $4,814.43 |
| Abatement value | $15,097.50 | $14,443.28 |
| Total over 63 months | $323,023.35 | $309,025.67 |
| Difference | $13,997.68 |
Pro rata share moves to 3.76%. No change proposed to the rate, term, abatement, or base year. Only the measured size.
Common area ceiling fully exposed and continuous. Enclosed rooms keep a standard grid with standard lay-in fixtures.
For the enclosed rooms to work for client calls, each needs a solid sealed lid above its grid rather than an open plenum. It is concealed, so the common area ceiling still reads as one uninterrupted plane.
The reference photo under Flooring shows the effect: exposed structure running over the top of glass-fronted offices.

One lite clear glass, full height, in a solid painted frame. Swing door with perimeter stop and weatherstrip.
Same door and frame, solid core with no glass. This room is used for calls and recording.
Reference image shown for style. Equivalent building standard product is fine.
We are asking for the common area slab to be polished rather than covered with resilient plank. The floor below is the finish we are after.
Reference: matte satin polish, salt and pepper, no aggregate exposure. Natural colour variation in the slab is expected and wanted.
The floor restrooms are single occupancy. On the other floors one has a urinal and one does not. We ask that both 5th floor restrooms be finished the same while the floor is open.